• AP, APR Series

    DIN mount split core AC current sensors based on PRiME air-core technology

    AP & APR Split-core transducers

    The AP and APR series are split-core current sensors designed to accommodate AC current ranges from 10A to 400A, adjustable via a switch. 

    These sensors are available in both RMS and True RMS versions and offer multiple output options, including 4-20mA, 0-5V, or 0-10V, which can be selected via a switch. They boast a wide bandwidth spanning from 30 Hz to 6 kHz and feature an 18 mm diameter aperture.

    While both series share similar characteristics, they also offer distinct features. The AP series is equipped with an RMS version, operates within a bandwidth of 30-2000 Hz, and is loop powered. On the other hand, the APR sensors come with a True RMS version and a broader bandwidth ranging from 30-6000 Hz.

    Both the AP and APR series offer B10 and B420L versions of their electronic components. The B10 variant refers to the sensors' voltage output capability (0-5 or 0-10 V DC), while the B420L variant pertains to the current output (4-20 mA DC) of the sensors.

    Utilizing the PRiME (Rogowski) air-core technology, the AP and APR sensors are primarily tailored for applications in the energy and automation sectors, where precise current measurement is essential.

    AP, APR – Features and benefits

    AP & APR split core current sensors

    Main characteristics

    • RMS output (AP) or True RMS output (APR)
    • Split-core type
    • 0-5 V DC and 0-10 V DC switch selectable voltage output (AP-B10, APR-B10) or Loop powered 4-20 mA current output (AP-B420L, APR-B420L)
    • DIN rail or Panel mounting
    • Switch selectable measuring ranges
    • Insulating plastic case recognized according to UL 94-V0

    Moreover, APR split-core sensors are equipped to measure VFD and SCR waveforms in current.

    Benefits

    • Large aperture for cable up to ? 18 mm
    • High insulation between primary and secondary circuits
    • Eliminates insertion loss
    • Easy installation

    Typical applications

    In the realm of energy and automation, both AP and APR product lines serve diverse applications. Specifically focusing on AP sensors, some notable applications include:

    • Automation systems: Analog current reading for remote monitoring (e.g. motor) and software alarms.
    • Panel meters: Simple connection to power consumption displays.

    In contrast, APR transducers are specifically engineered to cater to the following applications:

    • VFD Controlled Loads: VFD output indicates how the motor and attached load are operating.
    • SCR Controlled Loads: Accurate measurement of phase angle fired or burst fired (time proportioned) SCRs. Current measurement gives faster response than temperature measurement.
    • Switching Power Supplies and Electronic Ballasts: True RMS sensing is the most accurate way to measure power supply or ballast input power.

    LEM AP, APR – Download & Technical Characteristic

    AP SERIES


     

    Product

    Check stock

    DocumentPrimary nominal 
    RMS current
    Output TypeSecondary Nominal
    Signal Value
    Op. Temperature
    AP 50 B10Datasheet
    3D
    10 A, 25 A, 50 AVoltage0-5V-20 to 60 °C
    AP 50 B420LDatasheet
    3D
    10 A, 25 A, 50 ACurrent4-20mA-20 to 60 °C
    AP 100 B10Datasheet
    3D
    50 A, 75 A, 100 AVoltage0-5V-20 to 60 °C
    AP 100 B420LDatasheet
    3D
    50 A, 75 A, 100 ACurrent4-20mA-20 to 60 °C
    AP 200 B10Datasheet
    3D
    100 A, 150 A, 200 AVoltage0-5V-20 to 60 °C
    AP 200 B420LDatasheet
    3D
    100 A, 150 A, 200 ACurrent4-20mA-20 to 60 °C
    AP 400 B10Datasheet
    3D
    200 A, 300 A, 400 AVoltage0-5V-20 to 60 °C
    AP 400 B420LDatasheet
    3D
    200 A, 300 A, 400 ACurrent4-20mA-20 to 60 °C

     

    APR SERIES

     

    Product

    Check stock

    DocumentPrimary nominal 
    RMS current
    Output TypeSecondary Nominal
    Signal Value
    Secondary Nominal
    Signal Value
    APR 50 B10Datasheet
    3D
    10 A, 25 A, 50 AVoltage0-5V-20 to 60 °C
    APR 50 B420LDatasheet
    3D
    10 A, 25 A, 50 ACurrent4-20mA-20 to 60 °C
    APR 100 B10Datasheet
    3D
    50 A, 75 A, 100 AVoltage0-5V-20 to 60 °C
    APR 100 B420LDatasheet
    3D
    50 A, 75 A, 100 ACurrent4-20mA-20 to 60 °C
    APR 200 B10Datasheet
    3D
    100 A, 150 A, 200 AVoltage0-5V-20 to 60 °C
    APR 200 B420LDatasheet
    3D
    100 A, 150 A, 200 ACurrent4-20mA-20 to 60 °C
    APR 400 B10Datasheet
    3D
    200 A, 300 A, 400 AVoltage0-5V-20 to 60 °C
    APR 400 B420LDatasheet
    3D
    200 A, 300 A, 400 ACurrent4-20mA-20 to 60 °C

    AP, APR Sensors – ASK FOR SAMPLES / QUOTATIONS