• ART

    Unique, IPx7, thin, light, flexible, split-core AC Rogowski Coil current sensor from 10 to 10000 ARMS with Class accuracy 0.5 according to IEC 61869 regardless of primary conductor position and rated insulation voltage 1kV CATIII.

    Model details

    ART-B22-D70/SP3

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture. Output cable length: 3m

    Series
    ART
    Measurement
    電流センサ
    Nominal Value
    1000 A
    Measuring Range
    A
    Second. Nominal Signal
    電圧
    Second. Nominal Signal Value
    瞬時 V
    Primary Signal
    AC
    Supply Voltage
    セルフパワー
    Accuracy
    0.5 %
    Op. Temperature
    -40 °C / 80 °C
    技術
    ロゴウスキー
    Mounting
    一次側固定
    アプリケーション
    スマートグリッド
    ART-B22-D70/SP3
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    注文

    連絡先

    シリーズ

    同じシリーズの製品

    ART-B22-D125/SP25 3m, SMA

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. 3 m output cable with SMA crimp plug.

    ART-B22-D70/SP6

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture. Output cable length: 6m

    ART-B22-D300/SP4

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 300 mm aperture. Output cable length: 4.5m

    ART-B22-D300

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 300 mm aperture.

    ART-B22-D175/SP3

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 175 mm aperture. Output cable length: 3m

    ART-B22-D125/SP6

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. Output cable length:6m

    ART-B22-D125/SP4

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. Output cable length: 4.5m

    ART-B22-D70

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture.

    ART-B22-D175

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 175 mm aperture.

    ART-B22-D125

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture.