• ARU

    Unique, IP68, flexible, split-core AC Rogowski Coil current sensor from 1 to 300000 ARMS with Class accuracy 0.5 according to IEC 61869 regardless of primary conductor position and rated insulation voltage 1kV CATIII. Ruggerized for outdoor applications. UV, water, dust and ice resistant.

    モデル詳細

    ARU-B100-D125

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 125 mm aperture.

    シリーズ
    ARU
    測定
    電流センサ
    公稱値
    1000 A
    測定範囲
    A
    二次公稱信號
    電圧
    二次公稱信號値
    瞬時 V
    一次信號
    AC
    電源電圧
    セルフパワー
    精度
    0.5 %
    動作溫度
    -40 °C / 80 °C
    技術
    ロゴウスキー
    取り付け
    一次側固定
    アプリケーション
    オートメーション
    スマートグリッド
    ARU-B100-D125
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    代理店からのご注文

    在庫確認

    シリーズ

    同じシリーズの製品

    ARU-B100-D125/SP3

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 125 mm aperture, Output cable length 3m

    ARU-B100-D125/SP4

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 125 mm aperture, Output cable length 4.5 m

    ARU-B100-D125/SP6

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 125 mm aperture, Output cable length 6 m

    ARU-B100-D175

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 175 mm aperture.

    ARU-B100-D175/SP3

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 175 mm aperture, Output cable length 3m

    ARU-B100-D175/SP4

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 175 mm aperture, Output cable length 4.5 m

    ARU-B100-D175/SP6

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 175 mm aperture, Output cable length 6 m

    ARU-B100-D250

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 250 mm aperture.

    ARU-B100-D250/SP3

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 250 mm aperture, Output cable length 3m

    ARU-B100-D250/SP4

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 250 mm aperture, Output cable length 4.5 m

    ARU-B100-D250/SP6

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 250 mm aperture, Output cable length 6 m

    ARU-B100-D300

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 300 mm aperture.

    ARU-B100-D300/SP3

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 300 mm aperture, Output cable length 3m

    ARU-B100-D300/SP4

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 300 mm aperture, Output cable length 4.5 m

    ARU-B100-D300/SP6

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 300 mm aperture, Output cable length 6 m

    注文

    連絡先

    天天摸天天爽天天澡视频