• LV100xx

    Closed Loop Hall effect technology. DC, AC pulse voltage' measurements of 100 to 4000 VRMS nominal with galvanic isolation.To be panel mounted.

    Model details

    LV 100-1500

    1500 VRMS nominal.

    Series
    LV100xx
    Measurement
    電圧センサ
    Nominal Value
    1500 V
    Measuring Range
    2250 V
    Second. Nominal Signal
    電流
    Second. Nominal Signal Value
    瞬時 50 mA
    Primary Signal
    AC + DC
    Supply Voltage
    外部DCバイポーラ
    Supply Voltage Range
    15 - 15 V
    Accuracy
    0.9 %
    Op. Temperature
    70 °C
    技術
    クローズドループ?ホール効果
    Mounting
    パネル
    アプリケーション
    ドライブ
    電源
    再生可能エネルギー
    鉄道(車載)
    溶接
    LV 100-1500
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    ダウンロード

    Relative information

    注文

    連絡先

    シリーズ

    同じシリーズの製品

    LV 100-5000/SP1

    5000 VRMS nominal. +/- 15 to 24V +/- 10% power supply, -45°C to +85°C, Isolation test voltage 12kVRMS/50 Hz/1 min, Primary and secondary connections on M5 threaded studs, Shield, For traction.

    LV 100-750/SP8

    750 VRMS nominal. +/- 15 V power supply, -40°C to +80°C, Primary and secondary connections on M5 threaded studs, Shield, For traction.

    LV 100-750/SP4

    750 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, Shield, without electrolytic capacitors, For traction.

    LV 100-600/SP6

    600 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +75°C, Secondary connections on M5 threaded studs, Shield, For traction.

    LV 100-500/SP6

    500 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, For traction.

    LV 100-4000/SP6

    4000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -40°C to +85°C, Connection to primary by extra long studs, Secondary connections on M5 threaded studs, Shield, For traction.

    LV 100-4000/SP2

    4000 VRMS nominal. +/- 15 to +/- 24 V power supply, -25°C to +70°C, For traction.

    LV 100-3500/SP2

    3600 VRMS nominal. +/- 24 V power supply, -25°C to +70°C, For traction.

    LV 100-3000/SP3

    3000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -25°C to +70°C, For traction.

    LV 100-3000/SP12

    3000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -40°C to +85°C, Secondary connections on M5 threaded studs, For traction.

    LV 100-2000/SP6

    2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -40°C to +85°C, Secondary connections on M5 threaded studs, Shield, For traction.

    LV 100-2000/SP5

    2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 9 kVRMS isolation test voltage, -25°C to +70°C, For traction.

    LV 100-2000/SP18

    2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 9 kVRMS isolation test voltage, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, For traction.

    LV 100-2000/SP17

    2000 VRMS nominal. +/- 15 to +/- 24 V power supply, -25°C to +80°C, Primary and secondary connections on UNC 10-24 threaded studs, Shield, For traction.

    LV 100-2000/SP15

    2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 9 kVRMS isolation test voltage, -40°C to +75°C, Secondary connections on M5 threaded studs, Shield, For traction.

    LV 100-1500/SP3

    1500 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +85°C, Secondary connection on M5 threaded studs, For traction.

    LV 100-1000/SP9

    1000 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, For traction.

    LV 100-1000/SP16

    1000 VRMS nominal. +/- 15 to +/- 24 V power supply, -25°C to +70°C, Secondary connections on M5 threaded studs, For traction.

    LV 100-1000/SP13

    1000 VRMS nominal. +/- 16 to 33 V power supply, 12 kVRMS as isolation test voltage, -25°C to +70°C, For traction.