• CAS - CASR - CKSR

    CAS:

    Compact Fluxgate based current transducers single supplied (+5V).
    3 primary pins.


    CASR:

    Compact Fluxgate based current sensors single supplied (+5V) with reference access 3 primary pins.

    CKSR:

    Compact Fluxgate based current transducers single supplied (+5V) with reference access 4 primary pins.
    Higher creepage and clearance distances.
    ?

    CAS - CASR - CKSR

    CAS - CASR - CKSR

    Main characteristics:

    • Low offset and gain drift
    • Measuring range up to 3 x IPN
    • 12 multi-range models ( 4 models for each type)
    • PCB mounting
    • Small AC&DC isolated current measurements from 1.5 to 50 ARMS nominal (6A, 15A, 25A and 50A models)
    • Compact design
    • Only 2.93 cm2 as PCB mounting area is needed to support the 9g of these transducers
    • High accuracy at +85°C:
      • CAS: 2.5 to 3% of IPN
      • CASR & CKSR: 1.2 to 1.8% of IPN

    Features:

    • Isolation test voltage: up to 4.3KVRMS / 50 Hz / 1 min
    • Operating temperature range: -40°C to +85°C
    • Voltage output
    • Bandwidth DC to 300 KHz (+/- 3dB), 200KHz (+/- 1dB)
    • Fast response time <0.3μs
    • CASR & CKSR: Reference access on additional pin
    • CKSR: Different primary footprint with 4 pins for higher creepage and clearance distances (8.2 mm) for higher insulation
    • Each model is multi-range according to primary connection configuration