• ART

    Unique, IPx7, thin, light, flexible, split-core AC Rogowski Coil current sensor from 10 to 10000 ARMS with Class accuracy 0.5 according to IEC 61869 regardless of primary conductor position and rated insulation voltage 1kV CATIII.

    モデル詳細

    ART-B22-D125

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture.

    シリーズ
    ART
    測定
    電流センサ
    公稱値
    1000 A
    測定範囲
    A
    二次公稱信號
    電圧
    二次公稱信號値
    瞬時 V
    一次信號
    AC
    電源電圧
    セルフパワー
    精度
    0.5 %
    動作溫度
    -40 °C / 80 °C
    技術
    ロゴウスキー
    取り付け
    一次側固定
    アプリケーション
    スマートグリッド
    ART-B22-D125
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    代理店からのご注文

    在庫確認

    シリーズ

    同じシリーズの製品

    ART-B22-D125/SP100

    ART are calibrated & provided with a Class accuracy 0.5. LEM does not provide the integrator. Output voltage: 22.5 mV/kA. 70 mm aperture.

    ART-B22-D70/SP110 6m twist cable

    ART are calibrated & provided with a Class accuracy 0.5. LEM does not provide the integrator. Output voltage: 22.5 mV/kA. 70 mm aperture.

    ART-B22-D125/SP25 3m, SMA

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. 3 m output cable with SMA crimp plug.

    ART-B22-D175

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 175 mm aperture.

    ART-B22-D70

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture.

    ART-B22-D125/SP4

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. Output cable length: 4.5m

    ART-B22-D125/SP6

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. Output cable length:6m

    ART-B22-D175/SP3

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 175 mm aperture. Output cable length: 3m

    ART-B22-D300

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 300 mm aperture.

    ART-B22-D300/SP4

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 300 mm aperture. Output cable length: 4.5m

    ART-B22-D70/SP3

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture. Output cable length: 3m

    ART-B22-D70/SP6

    ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture. Output cable length: 6m