• FRS, FL

    Our new Open Loop Coreless Integral sensors (OLCI) for the electronic measurement of current up to 42kA

    FRS, FL - Open Loop Coreless Integral Sensors

    Our brand-new FRS and FL product families are designed for the electronic measurement of DC, AC, and pulsed current with galvanic separation between the primary and secondary circuits.

    The FRS current sensors allow the measurement of current up to 9000 A, while the FL sensors can reach up to 42 kA. Both product families are available with either a current output (4-20 mA) or an instantaneous voltage output (0-5 V).

    The main difference between the two product families lies in the size of the sensor: FRS sensors feature a 104 mm aperture, whereas FL sensors are available with either a 200 mm or a 300 mm aperture width.?

    Utilizing OLCI (Open Loop Coreless Integral) technology, FRS and FL coreless transducers ensure reliable and accurate current measurements in industrial, traction, and trackside applications.

    FRS, FL – Features and benefits

    FRS FL OLCI current sensors

    Features

    • Hall effect Open Loop Coreless Integral current sensor
    • Unipolar or Bi-polar measurement of primary current up to 42 kA
    • Instantaneous 4-20 mA current output or Instantaneous 0-5 V voltage output
    • Power supply +12 or +24 V DC
    • Galvanic separation between primary and secondary circuit
    • Factory calibrated

    While they can ensure unipolar or bi-polar measurement of primary current up to 9000 A, FRS sensors also feature:

    • High bandwidth > 1 MHz
    • Very low delay time up to < 400 ns

    Main characteristics

    • Wide measurement range
    • No magnetic offset
    • Low consumption and low losses
    • Wide range of rectangular busbar dimensions
    • Light weight design
    • M12 field connector

    In addition, FL current sensors are available with two aperture widths: 200 mm and 300 mm.

    Typical applications

    Both FRS and FL coreless high current sensors, known for their ability to measure DC, AC, and pulse currents, are widely used in a variety of industrial areas, as well as in traction and trackside applications. Examples of these applications include:

    • Wind turbine power converter
    • Electrolyser
    • High power drives

    FRS, FL transducers - Standards compliance

    FRS, FL Series
    IEC 62477-1: 2022
    IEC 61800-5-1: 2022
    IEC 62109-1: 2010
    IEC 61010-1: 2010
    EN 50155: 2021
    IEC 61992-7-2: 2006
    UL 61010-1: 3ED 2022

    LEM FRS, FL – Download & Technical Characteristic

    FRS Series


    Product Primary nominal RMS voltage Supply Voltage range Op. Temperature
    FRS 1000-S 1000 A 12 to 24 -40 to 85°C
    FRS 1000-SBI 1000 A 12 to 24 -40 to 85°C
    FRS 1500-SBI 1500 A 12 to 24 -40 to 85°C
    FRS 2000-S 2000 A 12 to 24 -40 to 85°C
    FRS 2000-SBI 2000 A 12 to 24 -40 to 85°C
    FRS 2000-SUI 2000 A 12 to 24 -40 to 85°C
    FRS 3000-S 3000 A 12 to 24 -40 to 85°C
    FRS 3000-SUI 3000 A 12 to 24 -40 to 85°C

    ?

    FL Series

    ?

    Product Primary nominal RMS voltage Supply Voltage range Op. Temperature
    FL 12000-SD200 12000 A 12 to 24 -40 to 85°C
    FL 12000-SDBI200 12000 A 12 to 24 -40 to 85°C
    FL 16000-SD300 16000 A 12 to 24 -40 to 85°C
    FL 16000-SDUI300 16000 A 12 to 24 -40 to 85°C
    FL 20000-SDBI200 20000 A 12 to 24 -40 to 85°C
    FL 28000-SD300 28000 A 12 to 24 -40 to 85°C
    FL 28000-SDBI200 28000 A 12 to 24 -40 to 85°C
    FL 28000-SDBI300 28000 A 12 to 24 -40 to 85°C
    FL 28000-SDUI300 28000 A 12 to 24 -40 to 85°C

    FRS, FL Sensors – ASK FOR SAMPLES / QUOTATIONS