• LA305

    Closed Loop Hall effect. DC, AC pulse currents' measurements of 300 ARMS nominal with galvanic isolation.To be panel mounted. Aperture 25.5 x 25.5 mm for the primary conductor crossing. Excellent accuracy, good response time, -10°C to + 85°C.

    Model details

    LA 305-S

    300 ARMS nominal

    Series
    LA305
    Measurement
    Current
    Nominal Value
    300 A
    Measuring Range
    500 A
    Second. Nominal Signal
    Current
    Second. Nominal Signal Value
    Instantaneous 120 mA
    Primary Signal
    AC + DC
    Supply Voltage
    External DC Bipolar
    Supply Voltage Range
    12 - 15 V
    Accuracy
    0.8 %
    Op. Temperature
    -10 °C / 85 °C
    Technology
    Closed loop Hall effect
    Mounting
    Panel
    Applications
    Drives
    Power Supplies
    Renewable Energies
    Welding
    LA 305-S
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Download

    Relative information

    Order from our distributors

    Check Stock

    Series

    Product of the same series

    LA 305-S/SP19

    500 ARMS nominal, turns ratio 1/3500, +/- 15 to +/- 24 V power supply, -40°c to +85°C, output on cable, shield, For traction

    LA 305-S/SP4

    300 ARMS nominal, -25°C to +85°C, output on M4 threaded studs, Potted. For traction

    LA 305-S/SP6

    300 ARMS nominal, Turns ratio 1/4000, +/- 15 to +/- 24 V power supply, Output on M4 threaded studs, Potted, For traction

    LA 305-S/SP8

    300 ARMS nominal, -40°C to +85°C, Output on Faston 6.3 x 0.8 mm, Potted, For traction

    Order

    Contact Information