• LF306

    Closed Loop Hall effect. DC, AC pulse currents' measurements of 300 ARMS nominal with galvanic isolation. Compact and ultra flat design. To be panel mounted in various ways. Aperture 25.5 x 25.5 mm for the primary conductor crossing. Excellent accuracy, good response time, Current output, -25°C to + 70°C. Dual supply +/- 12 to +/- 15 V.

    Model details

    LF 306-S

    300 ARMS nominal. Ultra flat design.

    Series
    LF306
    Measurement
    Current
    Nominal Value
    300 A
    Measuring Range
    500 A
    Second. Nominal Signal
    Current
    Second. Nominal Signal Value
    Instantaneous 150 mA
    Primary Signal
    AC + DC
    Supply Voltage
    External DC Bipolar
    Supply Voltage Range
    12 - 15 V
    Accuracy
    0.4 %
    Op. Temperature
    -25 °C / 70 °C
    Technology
    Closed loop Hall effect
    Mounting
    Panel
    Applications
    Drives
    Power Supplies
    Renewable Energies
    Welding
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Download

    Relative information

    Order

    Contact Information

    Series

    Product of the same series

    LF 306-S/SP10

    300 ARMS nominal. Secondary connections to be soldered on PCB