• LT2005

    Closed Loop Hall effect. DC, AC pulse currents' measurements of 2000 ARMS nominal with galvanic isolation. To be panel mounted. Aperture 60.5 x 20.5 mm or 56 mm diameter for the primary conductor crossing. Excellent accuracy, good response time, Current output, 0°C to + 70°C. Dual supply +/- 15 to +/- 24V.

    Model details

    LT 2005-S

    2000 ARMS nominal.

    Series
    LT2005
    Measurement
    Current
    Nominal Value
    2000 A
    Measuring Range
    3000 A
    Second. Nominal Signal
    Current
    Second. Nominal Signal Value
    Instantaneous 400 mA
    Primary Signal
    AC + DC
    Supply Voltage
    External DC Bipolar
    Supply Voltage Range
    15 - 24 V
    Accuracy
    0.3 %
    Op. Temperature
    70 °C
    Technology
    Closed loop Hall effect
    Mounting
    Panel
    Applications
    Drives
    Power Supplies
    Renewable Energies
    Welding
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Download

    Relative information

    Order

    Contact Information

    Series

    Product of the same series

    LT 2005-T/SP22

    2000 ARMS nominal. Special busbar integrated, -25°C to +70°C, +/- 24 V power supply, Test winding 100 turns, Shield, Hall cell at the bottom centered, For traction.

    LT 2005-T/SP2

    2000 ARMS nominal. Special busbar integrated, Turns ratio 1/4000, -40°C to +70°C, For traction.

    LT 2005-S/SP3

    1100 ARMS nominal. +/- 15 V power supply, -30°C to +70°C, Shield, Hall cell at the bottom centered, For traction.

    LT 2005-S/SP2

    2000 ARMS nominal. Turns ratio 1/4000, -40°C to +70°C, For traction.

    LT 2005-S/SP15

    2000 ARMS nominal. Turns ratio 1/5000, +/- 24 V power supply, -25°C to +70°C, Shield, Output on connector AMP CPC, Hall cell at 90°, For traction.