• LF505

    Closed Loop Hall effect. DC, AC pulse currents' measurements of 500 ARMS nominal with galvanic isolation. Compact design. To be panel mounted in various ways. Aperture 30.2 mm diameter for the primary conductor crossing. Excellent accuracy, good response time, Current output, -40°C to + 70°C. Dual supply +/- 15 to +/- 24V.

    Model details

    LF 505-S/SP39

    High mounting versatility, 500 ARMS nominal. Output on MOLEX Minifit jr 5566 with gold pins, -10°C to +70°C.

    Series
    LF505
    Measurement
    Current
    Nominal Value
    500 A
    Measuring Range
    800 A
    Second. Nominal Signal
    Current
    Second. Nominal Signal Value
    Instantaneous 100 mA
    Primary Signal
    AC + DC
    Supply Voltage
    External DC Bipolar
    Supply Voltage Range
    15 - 24 V
    Accuracy
    0.6 %
    Op. Temperature
    -10 °C / 70 °C
    Technology
    Closed loop Hall effect
    Mounting
    Panel
    Applications
    Drives
    Power Supplies
    Renewable Energies
    Welding
    LF 505-S/SP39
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Download

    Relative information

    Order from our distributors

    Check Stock

    Series

    Product of the same series

    LF 505-S/SP40

    High mounting versatility, 500 ARMS nominal. Turns ratio 1/3500, +/- 15 to 24 power supply, -40 to +70°C, Output on connector Mini Fit Jr.5566, For Traction

    LF 505-S

    High mounting versatility, 500 ARMS nominal.

    LF 505-S/SP15

    High mounting versatility, 500 ARMS nominal. Output on MOLEX Minifit jr 5566

    LF 505-S/SP22

    High mounting versatility, 500 ARMS nominal. Turns ratio 1/3500, Output on M4 threaded studs, For Traction

    LF 505-S/SP23

    High mounting versatility, 500 ARMS nominal. +/- 24 V power supply, -40°C to +85°C, Shield, Output on cable, For industry and traction.