• DVC-B

    LEM makes the voltage measurement more compact, 131.6 cm3 total volume, Fully-isolated nominal measurement of 1000 V DC, AC or pulsed, Compact, light (57 g) and robust package, Panel mounting, Rail DIN mounting adaptor as an option, 4.2kV as insulation test voltage, Meets latest industrial standards as well as IRIS requirements for rail traction applications

    Model details

    DVC 1000-B

    1000 VRMS nominal, Overall accuracy: +/- 1.7 % from -40°C to +85°C, 12 us response time, +/- 10 V instantaneous voltage output @ +/- 1500 V peak, +/- 15 to +/- 24 volt power supply

    Series
    DVC-B
    Measurement
    Voltage
    Nominal Value
    1000 V
    Measuring Range
    1500 V
    Second. Nominal Signal
    Voltage
    Second. Nominal Signal Value
    Instantaneous 6.66 V
    Primary Signal
    AC + DC
    Supply Voltage
    External DC Bipolar
    Supply Voltage Range
    15 - 24 V
    Accuracy
    1.7 %
    Op. Temperature
    -40 °C / 85 °C
    Technology
    Isolation Amplifier
    Mounting
    DIN rail
    Panel
    Applications
    Drives
    Power Supplies
    Renewable Energies
    Traction
    Welding
    DVC 1000-B
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Download