• DK

    Split Core (B series) and Solid Core (C series) DC current transducers for automation applications. Jumper selectable ranges. Split Core: current ranges from 50 A to 200 A. Solid Core: current ranges from 5 A to 100 A. Several output : 4-20 mA, 0-5V or 0-10 V. Bandwidth DC

    Model details

    DK 100 C10 U

    Unipolar DC Current range 50, 75 & 100A selectable by a jumper, Unipolar voltage output: 0-10 V DC @ + Ipn (0V @ -Ipn and @ 0 A), Solid core

    Series
    DK
    Measurement
    Current
    Nominal Value
    50 A, 75 A, 100 A
    Measuring Range
    100 A
    Second. Nominal Signal
    Voltage
    Second. Nominal Signal Value
    Instantaneous unidirectional 0-10V
    Primary Signal
    DC
    Supply Voltage
    External DC Unipolar
    Supply Voltage Range
    20 - 50 V
    Accuracy
    1 %
    Op. Temperature
    -20 °C / 50 °C
    Technology
    Open loop Hall effect
    Mounting
    Panel
    DIN rail
    Applications
    Automation
    Smart Grid
    DK 100 C10 U
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Download

    Relative information

    Order from our distributors

    Check Stock

    Series

    Product of the same series

    DK 100 B10

    DC Current range 50, 75 & 100A selectable by a jumper, Unipolar voltage output: 0-10 V DC @ +/- Ipn, Split core

    DK 100 B420

    DC Current range 50, 75 & 100A selectable by a jumper, Unipolar current output: 4-20 mA DC @ +/- Ipn, Split core

    DK 100 B420 U

    Unipolar DC Current range 50, 75 & 100A selectable by a jumper, Unipolar current output: 4-20 mA DC @ + Ipn (4 mA @ -Ipn and @ 0 A), Split core

    DK 100 B5

    DC Current range 50, 75 & 100A selectable by a jumper, Unipolar voltage output: 0-5 V DC @ +/- Ipn, Split core

    DK 100 C420 B

    Bipolar DC Current range 50, 75 & 100A selectable by a jumper, Current output: 4-20 mA DC @ + Ipn (4 mA @ -Ipn and 12 mA @ 0 A), Solid core

    DK 100 C420 U

    Unipolar DC Current range 50, 75 & 100A selectable by a jumper, Unipolar current output: 4-20 mA DC @ + Ipn (0 mA @ -Ipn and 4 mA @ 0 A), Solid core

    DK 100 C5 U

    Unipolar DC Current range 50, 75 & 100A selectable by a jumper, Unipolar voltage output: 0-5 V DC @ + Ipn (0 V @ -Ipn and @ 0 A), Solid core

    DK 20 C10 U

    Unipolar DC Current range 5, 10 & 20A selectable by a jumper, Unipolar voltage output: 0-10 V DC @ + Ipn (0 V @ -Ipn and @ 0 A), Solid core

    DK 20 C420 B

    Bipolar DC Current range 5, 10 & 20A selectable by a jumper, Current output: 4-20 mA DC @ + Ipn (4 mA @ -Ipn and 12 mA @ 0 A), Solid core

    DK 20 C420 U

    Unipolar DC Current range 5, 10 & 20A selectable by a jumper, Unipolar current output: 4-20 mA DC @ + Ipn (0 mA @ -Ipn and 4 mA @ 0 A), Solid core

    DK 20 C5 U

    Unipolar DC Current range 5, 10 & 20A selectable by a jumper, Unipolar voltage output: 0-5 V DC @ + Ipn (0 V @ -Ipn and @ 0 A), Solid core

    DK 200 B10

    DC Current range 100, 150 & 200A selectable by a jumper, Unipolar voltage output: 0-10 V DC @ +/- Ipn, Split core

    DK 200 B420

    DC Current range 100, 150 & 200A selectable by a jumper, Unipolar current output: 4-20 mA DC @ +/- Ipn, Split core

    DK 200 B420 B

    Bipolar DC Current range 100, 150 & 200A selectable by a jumper, Current output: 4-20 mA DC @ + Ipn (4 mA @ -Ipn and 12 mA @ 0 A), Split core

    DK 200 B420 U

    Unipolar DC Current range 100, 150 & 200A selectable by a jumper, Unipolar current output: 4-20 mA DC @ +/- Ipn, Split core (4 mA @ -Ipn and @ 0 A)

    DK 400 B420

    DC Current range 200, 300 & 400A selectable by a jumper, Unipolar current output: 4-20 mA DC @ +/- Ipn, Split core

    Order