• DK

    Split Core (B series) and Solid Core (C series) DC current transducers for automation applications. Jumper selectable ranges. Split Core: current ranges from 50 A to 200 A. Solid Core: current ranges from 5 A to 100 A. Several output : 4-20 mA, 0-5V or 0-10 V. Bandwidth DC

    Model details

    DK 100 B420

    DC Current range 50, 75 & 100A selectable by a jumper, Unipolar current output: 4-20 mA DC @ +/- Ipn, Split core

    Series
    DK
    Measurement
    Current
    Nominal Value
    50 A, 75 A, 100 A
    Measuring Range
    100 A
    Second. Nominal Signal
    Current
    Second. Nominal Signal Value
    Instantaneous Unipolar 4-20mA
    Primary Signal
    DC
    Supply Voltage
    External DC Unipolar
    Supply Voltage Range
    20 - 50 V
    Accuracy
    2 %
    Op. Temperature
    -20 °C / 50 °C
    Technology
    Open loop Hall effect
    Mounting
    Panel
    DIN rail
    Applications
    Automation
    Smart Grid
    DK 100 B420
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Download

    Relative information

    Order from our distributors

    Check Stock

    Series

    Product of the same series

    DK 100 B10

    DC Current range 50, 75 & 100A selectable by a jumper, Unipolar voltage output: 0-10 V DC @ +/- Ipn, Split core

    DK 100 B420 U

    Unipolar DC Current range 50, 75 & 100A selectable by a jumper, Unipolar current output: 4-20 mA DC @ + Ipn (4 mA @ -Ipn and @ 0 A), Split core

    DK 100 B5

    DC Current range 50, 75 & 100A selectable by a jumper, Unipolar voltage output: 0-5 V DC @ +/- Ipn, Split core

    DK 100 C10 U

    Unipolar DC Current range 50, 75 & 100A selectable by a jumper, Unipolar voltage output: 0-10 V DC @ + Ipn (0V @ -Ipn and @ 0 A), Solid core

    DK 100 C420 B

    Bipolar DC Current range 50, 75 & 100A selectable by a jumper, Current output: 4-20 mA DC @ + Ipn (4 mA @ -Ipn and 12 mA @ 0 A), Solid core

    DK 100 C420 U

    Unipolar DC Current range 50, 75 & 100A selectable by a jumper, Unipolar current output: 4-20 mA DC @ + Ipn (0 mA @ -Ipn and 4 mA @ 0 A), Solid core

    DK 100 C5 U

    Unipolar DC Current range 50, 75 & 100A selectable by a jumper, Unipolar voltage output: 0-5 V DC @ + Ipn (0 V @ -Ipn and @ 0 A), Solid core

    DK 20 C10 U

    Unipolar DC Current range 5, 10 & 20A selectable by a jumper, Unipolar voltage output: 0-10 V DC @ + Ipn (0 V @ -Ipn and @ 0 A), Solid core

    DK 20 C420 B

    Bipolar DC Current range 5, 10 & 20A selectable by a jumper, Current output: 4-20 mA DC @ + Ipn (4 mA @ -Ipn and 12 mA @ 0 A), Solid core

    DK 20 C420 U

    Unipolar DC Current range 5, 10 & 20A selectable by a jumper, Unipolar current output: 4-20 mA DC @ + Ipn (0 mA @ -Ipn and 4 mA @ 0 A), Solid core

    DK 20 C5 U

    Unipolar DC Current range 5, 10 & 20A selectable by a jumper, Unipolar voltage output: 0-5 V DC @ + Ipn (0 V @ -Ipn and @ 0 A), Solid core

    DK 200 B10

    DC Current range 100, 150 & 200A selectable by a jumper, Unipolar voltage output: 0-10 V DC @ +/- Ipn, Split core

    DK 200 B420

    DC Current range 100, 150 & 200A selectable by a jumper, Unipolar current output: 4-20 mA DC @ +/- Ipn, Split core

    DK 200 B420 B

    Bipolar DC Current range 100, 150 & 200A selectable by a jumper, Current output: 4-20 mA DC @ + Ipn (4 mA @ -Ipn and 12 mA @ 0 A), Split core

    DK 200 B420 U

    Unipolar DC Current range 100, 150 & 200A selectable by a jumper, Unipolar current output: 4-20 mA DC @ +/- Ipn, Split core (4 mA @ -Ipn and @ 0 A)

    DK 400 B420

    DC Current range 200, 300 & 400A selectable by a jumper, Unipolar current output: 4-20 mA DC @ +/- Ipn, Split core

    Order

    Contact Information

    天天摸天天爽天天澡视频