• DV

    Voltage transducers for Industrial and Traction - for medium and high voltage measurements from 1200 to 4200 VRMS with an unique compact design, excellent overall accuracy and high insulation voltage

    Model details

    DV 2000

    Bipolar and insulated measurement up to 2000 V, +/- 50 mA current output, Input & output connections on cables, Footprint compatible with CV4 and LV 200-AW/2 series.

    Series
    DV
    Measurement
    Voltage
    Nominal Value
    2000 V
    Measuring Range
    3000 V
    Second. Nominal Signal
    Current
    Second. Nominal Signal Value
    Instantaneous 50 mA
    Primary Signal
    AC + DC
    Supply Voltage
    External DC Bipolar
    Supply Voltage Range
    15 - 24 V
    Accuracy
    0.3 %
    Op. Temperature
    -40 °C / 85 °C
    Technology
    Insulation Digital Technology
    Mounting
    Panel
    Applications
    Drives
    Power Supplies
    Renewable Energies
    Traction
    Welding
    DV 2000
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Order

    Contact Information

    Series

    Product of the same series

    DV 3000/SP1

    3000 VRMS nominal, Bipolar and insulated measurement up to 4500 V, +/- 50 mA current output, Input on M5 studs on the side and output on M5 studs on the other side + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 6400

    6400 VRMS nominal, Bipolar and insulated measurement up to 9050 V, +/- 50 mA current output, Input on M5 studs on the top and output on M5 studs + Faston + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 4200/SP8

    Bipolar and insulated measurement up to 4200 V, +/- 50 mA current output, Input on M5 studs on the top and output on M5 studs + Faston + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 4200/SP4

    Bipolar and insulated measurement up to 4200 V, +/- 50 mA current output, Input and output on M5 studs + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 4200/SP3

    Bipolar and insulated measurement up to 4200 V, +/- 50 mA current output, Input and output on cables, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 4000/SP3

    Bipolar and insulated measurement up to 4000 V, +/- 50 mA current output, Input and output on M5 studs + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 4000/SP2

    Bipolar and insulated measurement up to 4000 V, +/- 50 mA current output, Input on M5 studs on the top, Output connections on Burndy connector, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 2800/SP4

    Bipolar and insulated measurement up to 2800 V, +/- 50 mA current output, Input and output connections on M5 studs, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 2000/SP2

    Bipolar and insulated measurement up to 2000 V, +/- 50 mA current output, Input & output connections on M5 studs, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 1500

    Bipolar and insulated measurement up to 1500 V, +/- 50 mA current output, Input connections on cables, Output connections on M5 studs or Faston, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 1200/SP2

    Bipolar and insulated measurement up to 1200 V, +/- 50 mA current output, Input on cables, Output connections on M5 and faston studs, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 1000

    Bipolar and insulated measurement up to 1000 V, +/- 50 mA current output, Input and output connections on cables, Footprint compatible with CV4 and LV 200-AW/2 series.