• DV

    Voltage transducers for Industrial and Traction - for medium and high voltage measurements from 1200 to 4200 VRMS with an unique compact design, excellent overall accuracy and high insulation voltage

    型號細節

    DV 2000

    Bipolar and insulated measurement up to 2000 V, +/- 50 mA current output, Input & output connections on cables, Footprint compatible with CV4 and LV 200-AW/2 series.

    系列
    DV
    測量類型
    電壓
    額定值
    2000 V
    測量范圍
    3000 V
    副邊輸出信號
    電流
    副邊輸出信號值
    瞬時 50 mA
    原邊信號
    AC + DC
    工作電壓
    外部供電 DC 雙向
    工作電壓范圍
    15 - 24 V
    精度
    0.3 %
    工作溫度
    -40 °C / 85 °C
    技術
    隔離數字技術
    安裝
    盤式
    應用
    驅動
    電源
    可再生能源
    牽引
    焊接
    DV 2000
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    向我們的經銷商訂購

    檢查庫存

    系列

    同系列產品

    DV 3000/SP1

    3000 VRMS nominal, Bipolar and insulated measurement up to 4500 V, +/- 50 mA current output, Input on M5 studs on the side and output on M5 studs on the other side + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 6400

    6400 VRMS nominal, Bipolar and insulated measurement up to 9050 V, +/- 50 mA current output, Input on M5 studs on the top and output on M5 studs + Faston + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 4200/SP8

    Bipolar and insulated measurement up to 4200 V, +/- 50 mA current output, Input on M5 studs on the top and output on M5 studs + Faston + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 1000

    Bipolar and insulated measurement up to 1000 V, +/- 50 mA current output, Input and output connections on cables, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 1200/SP2

    Bipolar and insulated measurement up to 1200 V, +/- 50 mA current output, Input on cables, Output connections on M5 and faston studs, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 1500

    Bipolar and insulated measurement up to 1500 V, +/- 50 mA current output, Input connections on cables, Output connections on M5 studs or Faston, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 2000/SP2

    Bipolar and insulated measurement up to 2000 V, +/- 50 mA current output, Input & output connections on M5 studs, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 2800/SP4

    Bipolar and insulated measurement up to 2800 V, +/- 50 mA current output, Input and output connections on M5 studs, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 4000/SP2

    Bipolar and insulated measurement up to 4000 V, +/- 50 mA current output, Input on M5 studs on the top, Output connections on Burndy connector, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 4000/SP3

    Bipolar and insulated measurement up to 4000 V, +/- 50 mA current output, Input and output on M5 studs + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 4200/SP3

    Bipolar and insulated measurement up to 4200 V, +/- 50 mA current output, Input and output on cables, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 4200/SP4

    Bipolar and insulated measurement up to 4200 V, +/- 50 mA current output, Input and output on M5 studs + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.