• CV3

    Compact voltage transducers for Industrial and Traction - for high accurate low and medium voltage measurements from 85 to 1400 VRMS with high bandwidth (short response time)

    Model details

    CV 3-1500

    1000V RMS nominal model, Voltage output 10 V/1500V.

    Series
    CV3
    Measurement
    Voltage
    Nominal Value
    1000 V
    Measuring Range
    1500 V
    Second. Nominal Signal
    Voltage
    Second. Nominal Signal Value
    Instantaneous 6.67 V
    Primary Signal
    AC + DC
    Supply Voltage
    External DC Bipolar
    Supply Voltage Range
    15 - 15 V
    Accuracy
    0.2 %
    Op. Temperature
    -40 °C / 85 °C
    Technology
    Closed loop Fluxgate C type
    Mounting
    Panel
    Applications
    Drives
    High Precision
    Power Supplies
    Renewable Energies
    Traction
    Welding
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Download

    Relative information

    Order

    Contact Information

    Series

    Product of the same series

    CV 3-500

    500V RMS nominal model, Voltage output 10 V/500V.

    CV 3-200/SP6

    100V RMS nominal model, Traction applications, -25°C to +75°C, Power supply from +/- 15 to +/- 24 V, Voltage output 5 V/120V.

    CV 3-200/SP5

    140V RMS nominal model, Traction applications, -25°C to +75°C, Power supply from +/- 15 to +/- 24 V, Voltage output 10 V/200V.

    CV 3-2000

    1400V RMS nominal model, Voltage output 10 V/2000V.

    CV 3-200

    140V RMS nominal model, Voltage output 10 V/200V.

    CV 3-1200

    840V RMS nominal model, Voltage output 10 V/1200V.

    CV 3-100/SP3

    85V RMS nominal model, Traction applications, -40°C to +85°C, Voltage output 5 V/100V.

    CV 3-1000

    700V RMS nominal model, Voltage output 10 V/1000V.