• CV4

    Compact voltage transducers for Industrial and Traction - for high accurate high voltage measurements from 2800 to 4242 VRMS with high insulation

    Model details

    CV 4-4000/SP1 SORTIE TENSION

    2800V RMS nominal model, Voltage output 10 V @ 4000 V, +/- 24 V power supply, -40°C to +70°C, Shield, Insulation test voltage: 9.5kVRMS, Overall accuracy: +/- 0.4 %, Output connector SUB- D 9 poles male

    Series
    CV4
    Measurement
    Voltage
    Nominal Value
    2800 V
    Measuring Range
    4000 V
    Second. Nominal Signal
    Voltage
    Second. Nominal Signal Value
    Instantaneous 7 V
    Primary Signal
    AC + DC
    Supply Voltage
    External DC Bipolar
    Supply Voltage Range
    24 - 24 V
    Accuracy
    0.4 %
    Op. Temperature
    -40 °C / 70 °C
    Technology
    Closed loop Fluxgate C type
    Mounting
    Panel
    Applications
    Drives
    High Precision
    Power Supplies
    Renewable Energies
    Traction
    Welding
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Download

    Relative information

    Order

    Contact Information

    Series

    Product of the same series

    CV 4-6000/SP2 SORTIE TENSION

    4200V RMS nominal model, Voltage output 10 V @ 6000 V, +/- 24 V power supply, -40°C to +70°C, Shield, Overall accuracy: +/- 0.4 %, Output connector SUB- D 9 poles male

    CV 4-6000/SP1 SORTIE COURANT

    4200V RMS nominal model, Current output 70 mA @ 4200 V, +/- 24 V power supply, -40°C to +70°C, Overall accuracy +/- 0.4 %, Output connector AMP CPC 11/4

    CV 4-4000/SP2 SORTIE COURANT

    2800V RMS nominal model, Current output 70 mA @ 2800 V, +/- 24 V power supply, -40°C to +70°C, Overall accuracy: +/- 0.4 %, Output connector SUB- D 9 poles male