• HAIS

    An easy way to measure AC @ DC currents from 50 to 400A RMS nominal with a compact unique design to be PCB mounted. 5 models with an aperture for the primary conductor or integrating the primary conductor for 50, 100 and 150 A models. Operating temperature range: -40 to +85°C. +5 V single supply. Reference access. Voltage output,Fixed offset and gain.

    Model details

    HAIS 150-TP

    150 A RMS nominal. With integrated busbar for primary

    Series
    HAIS
    Measurement
    Current
    Nominal Value
    150 A
    Measuring Range
    450 A
    Second. Nominal Signal
    Voltage
    Second. Nominal Signal Value
    Instantaneous 2.5 +/- 0.625 V
    Primary Signal
    AC + DC
    Supply Voltage
    External DC Unipolar
    Supply Voltage Range
    5 - 5 V
    Accuracy
    1 %
    Op. Temperature
    -40 °C / 85 °C
    Technology
    Open loop Hall effect
    Mounting
    PCB
    Applications
    Drives
    Power Supplies
    Renewable Energies
    Welding
    HAIS 150-TP
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Download

    Relative information

    Order from our distributors

    Check Stock