• LESR

    Closed Loop Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 3 to14 ppm/°C, -40°C to + 105°C, ?Reference access, Primary integrated conductors?, 100 % fully compatible with CASR xx-NP series

    Model details

    LESR 50-NP

    50 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 3 ppm/°C, -40°C to + 105°C, ?Reference access, Primary integrated conductors?, 100 % fully compatible with CASR 50-NP

    Series
    LESR
    Measurement
    Current
    Nominal Value
    50 A
    Measuring Range
    150 A
    Second. Nominal Signal
    Voltage
    Second. Nominal Signal Value
    Instantaneous 2.5 +/- 0.625 V
    Primary Signal
    AC + DC
    Supply Voltage
    External DC Unipolar
    Accuracy
    0.5 %
    Op. Temperature
    -40 °C / 85 °C
    Technology
    Closed loop Hall effect
    Mounting
    PCB
    Applications
    Drives
    Power Supplies
    Renewable Energies
    Welding
    LESR 50-NP
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Download

    Relative information

    Order

    Contact Information

    Series

    Product of the same series

    LESR 6-NP/SP1

    6 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 14 ppm/°C, -40°C to + 105°C, ?Reference access, Only 2 integrated primary conductors for differential measurement with 1 turn

    LESR 50-NP/SP1

    50 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 3 ppm/°C, -40°C to + 105°C, ?Reference access, Only 4 integrated primary conductors for differential measurement with 2 x 2 turns

    LESR 25-NP/SP1

    25 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 4 ppm/°C, -40°C to + 105°C, ?Reference access, Only 4 integrated primary conductors for differential measurement with 2 x 2 turns

    LESR 15-NP/SP1

    15 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 6 ppm/°C, -40°C to + 105°C, ?Reference access, Only 2 integrated primary conductors for differential measurement with 1 turn

    LESR 6-NP

    6 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 14 ppm/°C, -40°C to + 105°C, ?Reference access, Primary integrated conductors?, 100 % fully compatible with CASR 6-NP

    LESR 25-NP

    25 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 4 ppm/°C, -40°C to + 105°C, ?Reference access, Primary integrated conductors?, 100 % fully compatible with CASR 25-NP

    LESR 15-NP

    15 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 6 ppm/°C, -40°C to + 105°C, ?Reference access, Primary integrated conductors?, 100 % fully compatible with CASR 15-NP