• LF1005

    Closed Loop Hall effect. DC, AC pulse currents' measurements of 1000 ARMS nominal with galvanic isolation. Compact design. To be panel mounted in various ways. Aperture 40.5 x 13 or 38 mm diameter for the primary conductor crossing. Excellent accuracy, good response time, Current output, -40°C to + 85°C. Dual supply +/- 15 to +/- 24V.

    Model details

    LF 1005-S/SP33

    High mounting versatility, 1000 ARMS nominal. +/- 24 V power supply, Shield, Output on M4 threaded studs

    Series
    LF1005
    Measurement
    Current
    Nominal Value
    1000 A
    Measuring Range
    2000 A
    Second. Nominal Signal
    Current
    Second. Nominal Signal Value
    Instantaneous 200 mA
    Primary Signal
    AC + DC
    Supply Voltage
    External DC Bipolar
    Supply Voltage Range
    24 - 24 V
    Accuracy
    0.5 %
    Op. Temperature
    -40 °C / 85 °C
    Technology
    Closed loop Hall effect
    Mounting
    Panel
    Applications
    Traction
    LF 1005-S/SP33
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Download

    Relative information

    Order from our distributors

    Check Stock

    Series

    Product of the same series

    LF 1005-S

    1000 ARMS nominal. High mounting versatility

    LF 1005-S/SP14

    High mounting versatility, 1000 ARMS nominal, +/- 24 V power supply, Shield, Output on M4 threaded studs, For traction

    LF 1005-S/SP22

    High mounting versatility, 1000 ARMS nominal. Output on MOLEX Minifit 5566

    Order