• LV25

    For voltage measurements, a current proportional to the measured voltage must be passed through an external resistor R1, which is selected by the user and installed in series with the primary circuit of the transducer. Suitable for measuring nominal voltages from 10 V to up to 1500 V (depending on models). To be mounted on PCB.

    Model details

    LV 25-P

    10 mARMS nominal. Suitable for measuring nominal voltages from 10 V to up to 500 V

    Series
    LV25
    Measurement
    Current
    Nominal Value
    0.01 A
    Measuring Range
    0.014 A
    Second. Nominal Signal
    Current
    Second. Nominal Signal Value
    Instantaneous 25 mA
    Primary Signal
    AC + DC
    Supply Voltage
    External DC Bipolar
    Supply Voltage Range
    12 - 15 V
    Accuracy
    0.9 %
    Op. Temperature
    70 °C
    Technology
    Closed loop Hall effect
    Mounting
    PCB
    Applications
    Drives
    Power Supplies
    Renewable Energies
    Welding
    LV 25-P
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Download

    Relative information

    Order from our distributors

    Check Stock

    Series

    Product of the same series

    LV 25-P/SP5

    10 mARMS nominal. Suitable for measuring nominal voltages from 10 V to up to 1500 V. -40°C to +85°C. 4.2 kVRMS/50 Hz/1 min as isolation test voltage (4 kVDC/5 min).