• LV25

    For voltage measurements, a current proportional to the measured voltage must be passed through an external resistor R1, which is selected by the user and installed in series with the primary circuit of the transducer. Suitable for measuring nominal voltages from 10 V to up to 1500 V (depending on models). To be mounted on PCB.

    Model details

    LV 25-P/SP11

    Series
    LV25
    Measurement
    Voltage
    Nominal Value
    0.005 A
    Measuring Range
    0.0075 A
    Second. Nominal Signal
    Current
    Second. Nominal Signal Value
    Instantaneous 25 mA
    Supply Voltage
    External DC Bipolar
    Supply Voltage Range
    15 - 15 V
    Accuracy
    0.8 %
    Op. Temperature
    -25 °C / 70 °C
    Technology
    Closed loop Hall effect
    Mounting
    PCB
    LV 25-P/SP11
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    Download

    Relative information

    Order from our distributors

    Check Stock

    Series

    Product of the same series

    LV 25-P

    10 mARMS nominal. Suitable for measuring nominal voltages from 10 V to up to 500 V

    LV 25-P/SP5

    10 mARMS nominal. Suitable for measuring nominal voltages from 10 V to up to 1500 V. -40°C to +85°C. 4.2 kVRMS/50 Hz/1 min as isolation test voltage (4 kVDC/5 min).

    Order

    Contact Information

    天天摸天天爽天天澡视频