• ARU

    Unique, IP68, flexible, split-core AC Rogowski Coil current sensor from 1 to 300000 ARMS with Class accuracy 0.5 according to IEC 61869 regardless of primary conductor position and rated insulation voltage 1kV CATIII. Ruggerized for outdoor applications. UV, water, dust and ice resistant.

    型號細節

    ARU-B100-D125

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 125 mm aperture.

    系列
    ARU
    測量類型
    電流
    額定值
    1000 A
    測量范圍
    A
    副邊輸出信號
    電壓
    副邊輸出信號值
    瞬時 V
    原邊信號
    AC
    工作電壓
    自供電
    精度
    0.5 %
    工作溫度
    -40 °C / 80 °C
    技術
    羅氏線圈
    安裝
    原邊固定
    應用
    自動化
    智能電網
    ARU-B100-D125
    PICTURE
    FRONT
    BACK
    LEFT
    RIGHT
    下載

    相關信息

    向我們的經銷商訂購

    檢查庫存

    系列

    同系列產品

    ARU-B100-D125/SP3

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 125 mm aperture, Output cable length 3m

    ARU-B100-D125/SP4

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 125 mm aperture, Output cable length 4.5 m

    ARU-B100-D125/SP6

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 125 mm aperture, Output cable length 6 m

    ARU-B100-D175

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 175 mm aperture.

    ARU-B100-D175/SP3

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 175 mm aperture, Output cable length 3m

    ARU-B100-D175/SP4

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 175 mm aperture, Output cable length 4.5 m

    ARU-B100-D175/SP6

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 175 mm aperture, Output cable length 6 m

    ARU-B100-D250

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 250 mm aperture.

    ARU-B100-D250/SP3

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 250 mm aperture, Output cable length 3m

    ARU-B100-D250/SP4

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 250 mm aperture, Output cable length 4.5 m

    ARU-B100-D250/SP6

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 250 mm aperture, Output cable length 6 m

    ARU-B100-D300

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 300 mm aperture.

    ARU-B100-D300/SP3

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 300 mm aperture, Output cable length 3m

    ARU-B100-D300/SP4

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 300 mm aperture, Output cable length 4.5 m

    ARU-B100-D300/SP6

    ARU are calibrated & provided with a Class accuracy 0.5. ARU needs an integrator at its output. Output voltage: 100 mV/kA. 300 mm aperture, Output cable length 6 m