• DVL

    Compact and high accuracy voltage sensors for Industrial and Traction applications

    DVL - Voltage Sensors

    The DVL product family constitutes a compact voltage sensor range designed to ensure high accuracy in both industrial and traction applications. Engineered for the electronic measurement of voltages, including DC, AC, and pulsed voltages, these sensors feature galvanic separation between the primary and secondary circuits.

    Tailored for small and medium voltage measurements ranging from 50 to 2000 VRMS, DVL voltage sensors boast a unique compact design, providing a 30% reduction in weight and power consumption. They deliver excellent overall accuracy and are fully compatible with previous generations of transducers, such as the LV100 product family, in terms of performance and footprint.

    Operating with our patented insulation digital technology, the DVL components combine low consumption, very high accuracy, and minimal temperature drift.

    DVL – Features and benefits

    DVL voltage

    Features

    • Bipolar and insulated measurement up to 3000 V
    • Current output
    • Input and output connections with M5 studs
    • Compatible with AV 100 family

    The DVL-UI electronic components come with their own features:

    • Unipolar and insulated measurement of positive voltage up to 1500 V
    • 4-20 mA output

    Just like the rest of the DVL family, they are designed with input and output connections with M5 studs. In addition, they are also compatible with LV 100 product family.

    Main characteristics

    • A unique design to cover all measuring ranges
    • Low consumption and low losses
    • Compact design
    • Good behavior under common mode variations
    • Excellent accuracy (offset, sensitivity, linearity)
    • Good delay time
    • Low temperature variation
    • High immunity to external interferences.?

    Typical applications

    DVL sensors are frequently employed in both railway settings (including fixed installations and onboard trains) and industrial applications. It is customary to encounter DVL sensors in the following applications:

    The DVL-UI components are specifically designed for particular application fields, demonstrating optimal performance in substations and trackside applications.

    DVL voltage sensors - Standard compliance

    The DVL family is compliant with many standards applicable in the industry and traction markets:?

    • EN50155:2007 for traction applications
    • European Directive EMC 2004 / 108 / EEC: CE Marking
    • Using UL94-VO recognized materials
    • EN 50121-3-2:2006: Railway EMC standard
    • EN 50124-1:2001: Insulation levels
    • EN 50178:1997: for industrial applications
    • NFF 16101/2: Fire and smoke classification
    • Developed according to IRIS standard

    LEM DVL – Download & Technical Characteristic

    Product Document Primary nominal RMS voltage Secondary Nominal Signal Supply Voltage range Op. Temperature
    DVL 50

    Datasheet
    3D

    50 V Current 15 to 24 -40 to 85°C
    DVL 50-UI

    Datasheet
    3D

    50 V Current 15 to 24 -40 to 85°C
    DVL 125 Datasheet
    3D
    125 V Current 15 to 24 -40 to 85°C
    DVL 150 Datasheet
    3D
    150 V Current 15 to 24 -40 to 85 °C
    DVL 150-UI Datasheet
    3D
    150 V Current 15 to 24 -40 to 85°C
    DVL 150/SP1 Datasheet
    3D
    150 V Current 15 to 24 -40 to 85°C
    DVL 250 Datasheet
    3D
    250 V Current 15 to 24 -40 to 85°C
    DVL 250-UI Datasheet
    3D
    250 V Current 15 to 24 -40 to 85°C
    DVL 500 Datasheet
    3D
    500 V Current 15 to 24 -40 to 85°C
    DVL 500-UI Datasheet
    3D
    500 V Current 15 to 24 -40 to 85°C
    DVL 750/SP5 Datasheet
    3D
    750 V Voltage 15 to 24 -40 to 85°C
    DVL 750 Datasheet
    3D
    750 V Current 15 to 24 -40 to 85°C
    DVL 750-UI Datasheet
    3D
    750 V Current 15 to 24 -40 to 85°C
    DVL 750/SP3 Datasheet
    3D
    750 V Current 15 to 24 -40 to 85°C
    DVL 750/SP4 Datasheet
    3D
    750 V Current 15 to 24 -40 to 85°C
    DVL 1000 Datasheet
    3D
    1000 V Current 15 to 24 -40 to 85°C
    DVL 1000-UI Datasheet
    3D
    1000 V Current 15 to 24 -40 to 85°C
    DVL 1000/SP1 Datasheet
    3D
    1000 V Current 15 to 24 -40 to 85°C
    DVL 1000/SP5 Datasheet
    3D
    1000 V Current 15 to 24 -40 to 85°C
    DVL 1000/SP7 Datasheet
    3D
    1000 V Current 15 to 24 -40 to 85°C
    DVL 1000/SP8 Datasheet
    3D
    1000 V Current 15 to 24 -40 to 85°C
    DVL 1000/SP9 Datasheet
    3D
    1000 V Voltage 15 to 24 -40 to 85°C
    DVL 1500 Datasheet
    3D
    1500 V Current 15 to 24 -40 to 85°C
    DVL 1500-UI Datasheet
    3D
    1500 V Current 15 to 24 -40 to 85°C
    DVL 1500/SP1 Datasheet
    3D
    1500 V Current 15 to 24 -40 to 85°C
    DVL 1500/SP5 Datasheet
    3D
    1500 V Current 15 to 24 -40 to 85°C
    DVL 1500/SP6 Datasheet
    3D
    1500 V Current 15 to 24 -40 to 85°C
    DVL 1500/SP8 Datasheet
    3D
    1500 V Current 15 to 24 -40 to 85°C
    DVL 1500/SP7 Datasheet
    3D
    1500 V Voltage 15 to 24 -40 to 85°C
    DVL 2000 Datasheet
    3D
    2000 V Current 15 to 24 -40 to 85°C
    DVL 2000/SP1 Datasheet
    3D
    2000 V Current 15 to 24 -40 to 85°C
    DVL 2000/SP5 Datasheet
    3D
    2000 V Current 15 to 24 -40 to 85°C
    DVL 2000/SP6 Datasheet
    3D
    2000 V Current 15 to 24 -40 to 85°C
    DVL 2000/SP9 Datasheet
    3D
    2000 V Current 15 to 24 -40 to 85°C

    DVL Sensors – ASK FOR SAMPLES / QUOTATIONS

    Looking to receive samples or a quotation? Please click on the contact button below and provide us with the information you need on this product series. Our sales team will get back to you shortly.

    Contact Us