• DV

    Voltage transducers for Industrial and Traction - for medium and high voltage measurements from 1200 to 4200 VRMS with an unique compact design, excellent overall accuracy and high insulation voltage

    型號細節

    DV 4000/SP3

    Bipolar and insulated measurement up to 4000 V, +/- 50 mA current output, Input and output on M5 studs + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

    系列
    DV
    測量類型
    電壓
    額定值
    4000 V
    測量范圍
    6000 V
    副邊輸出信號
    電流
    副邊輸出信號值
    瞬時 50 mA
    原邊信號
    AC + DC
    工作電壓
    外部供電 DC 雙向
    工作電壓范圍
    15 - 24 V
    精度
    0.3 %
    工作溫度
    -40 °C / 85 °C
    技術
    隔離數字技術
    安裝
    盤式
    應用
    牽引
    DV 4000/SP3
    向我們的經銷商訂購

    檢查庫存

    系列

    同系列產品

    DV 3000/SP1

    3000 VRMS nominal, Bipolar and insulated measurement up to 4500 V, +/- 50 mA current output, Input on M5 studs on the side and output on M5 studs on the other side + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 6400

    6400 VRMS nominal, Bipolar and insulated measurement up to 9050 V, +/- 50 mA current output, Input on M5 studs on the top and output on M5 studs + Faston + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 4200/SP8

    Bipolar and insulated measurement up to 4200 V, +/- 50 mA current output, Input on M5 studs on the top and output on M5 studs + Faston + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 1000

    Bipolar and insulated measurement up to 1000 V, +/- 50 mA current output, Input and output connections on cables, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 1200/SP2

    Bipolar and insulated measurement up to 1200 V, +/- 50 mA current output, Input on cables, Output connections on M5 and faston studs, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 1500

    Bipolar and insulated measurement up to 1500 V, +/- 50 mA current output, Input connections on cables, Output connections on M5 studs or Faston, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 2000

    Bipolar and insulated measurement up to 2000 V, +/- 50 mA current output, Input & output connections on cables, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 2000/SP2

    Bipolar and insulated measurement up to 2000 V, +/- 50 mA current output, Input & output connections on M5 studs, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 2800/SP4

    Bipolar and insulated measurement up to 2800 V, +/- 50 mA current output, Input and output connections on M5 studs, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 4000/SP2

    Bipolar and insulated measurement up to 4000 V, +/- 50 mA current output, Input on M5 studs on the top, Output connections on Burndy connector, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 4200/SP3

    Bipolar and insulated measurement up to 4200 V, +/- 50 mA current output, Input and output on cables, Footprint compatible with CV4 and LV 200-AW/2 series.

    DV 4200/SP4

    Bipolar and insulated measurement up to 4200 V, +/- 50 mA current output, Input and output on M5 studs + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

    訂單