• LA Series

    DC, AC pulse currents' measurements of 0.25 ARMS to 500 ARMS nominal with galvanic isolation

    LA Series – Current Sensors

    The LA Series current sensors are closed?loop Hall?effect transducers designed for the precise measurement of DC, AC, and pulsed currents while providing reinforced galvanic isolation between the primary and secondary circuits. Covering a broad range of nominal currents, from 5 Arms up to 500 Arms depending on the model, the LA series offers multiple form factors and mounting options to support diverse integration requirements across industrial and railway environments.

    Most LA parts are designed for printed circuit board (PCB) mounting, featuring compact housings and primary conductor apertures adapted for plug?type crossings, with sizes varying by model. These PCB?mount sensors are recognized for their excellent accuracy and fast response times, making them highly suited for industrial applications.

    Several higher?current models, such as LA 205, LA 305, and LA 306, are intended for panel mounting and include larger primary apertures to accommodate thicker conductors. The LA 306 variant is specifically oriented toward industrial applications.

    The LA 200?500 SD represents a distinct product within the LA Series. It is a split?core, panel?mount current sensor featuring a large 67 × 67 mm aperture, enabling easy installation around existing conductors. Built on closed?loop Hall?effect technology, it delivers high accuracy and fast response times, particularly suited for traction and railway current measurement applications.

    Across the entire LA Series, the combination of closed?loop architecture, galvanic isolation, and optimized mechanical design ensures reliable and precise current measurement in demanding environments.

    LA Series – Features and benefits

    LA current sensors

    Main characteristics

    • Closed?loop (compensated) Hall effect current transducers
    • Galvanic isolation between primary and secondary circuits
    • Insulating plastic case recognized according to UL 94?V0
    • Standard current output
    • PCB?mount design for the majority of models (LA 25 to LA 200, LA 130/150, LA 55/100)
    • Panel?mount design for higher?current models (LA 205, LA 305, LA 306)
    • Split?core design for LA 200–500 SD (allows installation without cutting the primary conductor)

    Benefits

    • Excellent accuracy
    • Very good linearity
    • Low temperature drift
    • Optimized response time
    • Wide frequency bandwidth
    • High immunity to external magnetic interference
    • No insertion losses
    • Current overload capability

    Typical applications

    Industrial applications

    (All LA models except LA 200–500 SD are designed primarily for industrial use.)

    Traction applications

    (Only for LA 200–500 SD, the split?core version.)

    • Propulsion & braking choppers
    • Propulsion converters
    • Auxiliary converters
    • Battery chargers
    • Energy meters

    LEM LA – Download & Technical Characteristic

    Product

    Check stock

    DocumentNominal valueSupply Voltage rangeOp. Temperature
    LA 25-NP

    Datasheet
    3D
    5 A, 6 A, 8 A, 12 A, 25 A15 to 15-40 to 85°C
    LA 25-NP/SP11

    Datasheet1 A15 to 150 to 70 °C
    LA 25-NP/SP39

    Datasheet2 A15 to 15-40 to 85°C
    LA 25-NP/SP13

    Datasheet0.5 A15 to 15-40 to 70°C
    LA 25-NP/SP14

    Datasheet0.25 A15 to 15-10 to 70 °C
    LA 25-NP/SP38 Datasheet0.4 A15 to 15-40 to 85°C
    LA 25-NP/SP25

    Datasheet
    3D
    5 A, 6 A, 8 A, 12 A, 25 A15 to 15-40 to 85°C
    LA 25-NP/SP34

    Datasheet1.5 A15 to 15-40 to 85°C
    LA 25-NP/SP7

    Datasheet2.5 A15 to 150 to 70 °C
    LA 25-NP/SP8

    Datasheet2 A15 to 150 to 70 °C
    LA 10-PB Datasheet
    3D
    10 A15 to 15-20 to 80°C
    LA 25-NP/SP9

    Datasheet1.5 A15 to 150 to 70 °C
    LA 35-NP/SP3 Datasheet17.5 A15 to 15-25 to 70 °C
    LA 35-NP

    Datasheet
    3D
    7 A, 8 A, 11 A, 17 A, 35 A15 to 15-25 to 70 °C
    LA 25-P

    Datasheet
    3D
    12,5 A12 to 15-25 to 85°C
    LA 55-P

    Datasheet
    3D
    50 A12 to 15-40 to 85°C
    LA 55-P/SP1

    Datasheet
    3D
    50 A12 to 15-40 to 85 °C
    LA 55-P/SP11

    Datasheet50 A15 to 15-40 to 85 °C
    LA 55-P/SP2

    Datasheet50 A14 to 14-40 to 85 °C
    LA 55-P/SP21

    Datasheet50 A12 to 15-40 to 85 °C
    LA 55-P/SP23

    Datasheet50 A12 to 15-40 to 85 °C
    LA 55-P/SP26

    Datasheet50 A12 to 15-40 to 85 °C
    LA 55-P/SP7

    Datasheet50 A12 to 15-40 to 85 °C
    LA 55-TP

    Datasheet
    3D
    50 A12 to 15-40 to 85 °C
    LA 55-TP/SP1

    Datasheet50 A12 to 15-40 to 85°C
    LA 55-TP/SP27

    Datasheet50 A12 to 15-40 to 85°C
    LA 55-TP/SP28 Datasheet50 A12 to 15-40 to 85°C
    LA 100-TP/SP2 Datasheet60 A15 to 150 to 70 °C
    LA 100-P/SP6 Datasheet85 A12 to 15-40 to 85°C
    LA 100-P

    Datasheet100 A12 to 15-40 to 85 °C
    LA 100-P/SP13

    Datasheet100 A12 to 15-25 to 70 °C
    LA 100-P/SP4 Datasheet100 A12 to 15-40 to 85 °C
    LA 100-TP

    Datasheet100 A12 to 15-40 to 85 °C
    LA 100-TP/SP10 Datasheet
    3D
    100 A12 to 15-40 to 85 °C
    LA 100-TP/SP7 Datasheet100 A12 to 15-40 to 85 °C
    LA 125-P

    Datasheet
    3D
    125 A12 to 15-40 to 85°C
    LA 125-P/SP1

    Datasheet
    3D
    125 A12 to 15-25 to 85 °C
    LA 125-P/SP16 Datasheet
    3D
    125 A12 to 15-25 to 85 °C
    LA 125-P/SP3

    Datasheet125 A12 to 15-25 to 85 °C
    LA 125-P/SP4

    Datasheet125 A12 to 15-40 to 85 °C
    LA 125-P/SP7

    Datasheet125 A12 to 15-25 to 85 °C
    LA 130-P

    Datasheet
    3D
    130 A12 to 15-40 to 85°C
    LA 130-P/SP1

    Datasheet
    3D
    130 A12 to 15-40 to 85 °C
    LA 150-P

    Datasheet
    3D
    150 A12 to 15-40 to 85 °C
    LA 150-P/SP1

    Datasheet
    3D
    150 A12 to 15-40 to 85 °C
    LA 150-TP

    Datasheet
    3D
    150 A12 to 15-40 to 85°C
    LA 150-TP/SP1

    Datasheet
    3D
    150 A12 to 15-40 to 85°C
    LA 205-S/SP15 Datasheet200 A12 to 15-40 to 85°C
    LA 200-P

    Datasheet
    3D
    200 A12 to 15-40 to 85°C
    LA 200-P/SP10 Datasheet200 A12 to 15-25 to 85 °C
    LA 200-P/SP12

    Datasheet200 A15 to 150 to 45 °C
    LA 200-P/SP14 Datasheet
    3D
    200 A15 to 15-25 to 85 °C
    LA 200-P/SP3

    Datasheet200 A15 to 150 to 45 °C
    LA 200-P/SP4

    Datasheet200 A12 to 15-25 to 85 °C
    LA 205-S

    Datasheet
    3D
    200 A15 to 12-10 to 85 °C
    LA 205-S/SP1

    Datasheet200 A15 to 12-10 to 85 °C
    LA 205-S/SP21

    Datasheet
    3D
    300 A24 to 15-40 to 85 °C
    LA 205-S/SP33

    Datasheet300 A15 to 15-40 to 70 °C
    LA 205-S/SP6

     

    Datasheet
    3D
    200 A15 to 12-40 to 85 °C
    LA 205-T/SP16

    Datasheet
    3D
    200 A24 to 15-25 to 75 °C
    LA 200-SD/SP3Datasheet
    3D
    200 A24 to 24-30 to 70 °C
    LA 255-S

    Datasheet
    3D
    250 A18 to 12-10 to 85 °C
    LA 305-S

    Datasheet
    3D
    300 A15 to 12-10 to 85 °C
    LA 305-S/SP1

    Datasheet500 A15 to 12-10 to 85 °C
    LA 305-S/SP19

    Datasheet
    3D
    500 A24 to 15-40 to 85 °C
    LA 305-S/SP4

     

    Datasheet
    3D
    300 A15 to 12-25 to 85 °C
    LA 305-S/SP5

    Datasheet300 A15 to 12-10 to 85 °C
    LA 305-S/SP6

    Datasheet
    3D
    300 A24 to 15-25 to 85 °C
    LA 305-S/SP8

    Datasheet
    3D
    300 A15 to 12-40 to 85 °C
    LA 306-S

    Datasheet
    3D
    300 A15 to 15-40 to 85 °C
    LA 306-S/SP1

    Datasheet400 A15 to 15-40 to 85 °C
    LA 306-S/SP4 Datasheet480 A15 to 15-40 to 70 °C
    LA 306-S/SP2

    Datasheet300 A24 to 24-40 to 75 °C
    LA 200-SD/SP4 Datasheet
    3D
    200 A24 to 24-40 to 85 °C

    LA sensors – ASK FOR SAMPLES / QUOTATIONS

    Looking to receive samples or a quotation? Please click on the contact button below and provide us with the information you need on this product series. Our sales team will get back to you shortly.

    Contact Us

    天天摸天天爽天天澡视频